Measure the load
Add the operating watts of equipment that must run simultaneously.
Learn how to size batteries, understand watt-hours, choose an inverter and estimate real runtime without relying on optimistic marketing numbers.
The order matters: identify the load first, then stored energy, output limits and finally runtime.
Add the operating watts of equipment that must run simultaneously.
Use watt-hours directly or calculate volts × amp-hours for a battery bank.
Continuous and startup watts must both fit the inverter or UPS.
Apply usable capacity, conversion efficiency and idle consumption.
Watts describe the rate at which a device uses power at a moment. Watt-hours describe energy accumulated over time. A steady 100 W device running for five hours consumes about 500 Wh before conversion losses. Start with the home appliance wattage chart when you do not know the load.
Portable power stations often state capacity in Wh. Individual batteries commonly state voltage and amp-hours. Multiply bank voltage by total bank Ah to estimate nominal energy. Batteries wired in series increase voltage but do not add amp-hours; parallel strings add amp-hours while voltage stays the same.
The inverter rating answers whether it can power the load; the battery capacity answers for how long. Keep these questions separate. The continuous rating should exceed the simultaneous operating load with reasonable headroom. VA is not stored energy and should never be entered as Wh.
Refrigerators, freezers, pumps, fans and air conditioners may briefly demand much more power when starting. Check the equipment documentation or use an appropriate meter with surge capture. The backup system must satisfy both continuous output and short-duration surge requirements.
Nameplate capacity is not fully delivered to the appliance. Depth-of-discharge limits, inverter losses and the inverter's own idle draw reduce runtime. Variable loads such as refrigerators need average consumption or a realistic duty cycle instead of continuous running watts.
Measure critical equipment, confirm manufacturer specifications and leave headroom. Battery wiring, fusing, ventilation, conductor sizing and protective devices require appropriate technical judgment. For medical, safety or business-critical loads, use qualified professional advice and test the complete system before an outage.
Choose the tool matching the specification label you already have.
Estimate portable power station runtime with appliance load, inverter losses and idle draw.
Open calculator →Battery labeled V and AhCalculate runtime for 12 V, 24 V or 48 V lead-acid, AGM and LiFePO4 banks.
Open calculator →Cycling compressor loadUse daily kWh or running watts and duty cycle with startup-surge validation.
Open calculator →Multiple office devicesBuild a complete workstation load and check continuous and peak power.
Open calculator →Compact refrigerator planningCompare running watts, startup surge, daily energy use and a worked 500 Wh runtime example.
Read guide →Running watts, surge and kWhSeparate compressor running power from startup surge and daily energy, then work through a realistic battery-backup example.
Read guide →kWh, Ah, DoD and backup daysCalculate nameplate kWh, amp-hours, battery count and supporting solar power with a complete worked example.
Read guide →The guides are organized into focused clusters so each future article answers one real planning question and links directly to a useful tool.
Watt-hours, amp-hours, series versus parallel, depth of discharge, battery aging and cold-weather capacity.
Core education clusterRefrigerators, home offices, pumps, fans, CPAP equipment and other practical backup loads.
High-intent traffic clusterContinuous rating, surge limits, efficiency, idle draw and choosing capacity for a target runtime.
Commercial-intent clusterIt depends on which loads must operate and for how long. Add the required appliance watts, then calculate energy for the target hours with efficiency losses.
Nameplate Wh is useful, but delivered AC energy is lower because of usable-capacity limits, inverter conversion and idle draw.
Start with the simultaneous running load and the largest expected startup demand. Then select output capacity and battery energy.
No. Solar input varies with weather, orientation, season and charge-controller limits. Calculate battery-only runtime first, then model solar separately.